Fluoropolymer heaters in steam-heated acid service, as seen in digesters, hydrolysers, and chemical reactors, are exposed to a combination of high-temperature steam (120–180°C) and aggressive acids (H₂SO₄, HNO₃, HCl, H₃PO₄). Two fluoropolymers are the leaders in this service: PFA (perfluoroalkoxy) and FEP (fluorinated ethylene propylene). Their long-term hydrolytic stability-resistance to degradation by steam and hot acids-varies widely. PFA has a greater temperature for continuous use (200°C compared with 180°C for FEP) and better resistance to permeability by steam and attack by acids. FEP has a lower melting point (255°C against 305°C for PFA) and is more vulnerable to stress cracking in the presence of steam and acid vapours. For long term service (5+ years) in steam heated acid combinations at temperatures >150 stupňov, PFA je 3-5x lepšia ako FEP. Obe sú výrazne pod 130 stupňov. Zásadným rozdielom medzi polymérmi je ich odolnosť voči hydrolytickému štiepeniu reťazcov pri zvýšených teplotách, kde zvýšená molekulová hmotnosť PFA a stabilnejšie perfluóralkoxy bočné reťazce majú výhodu v trvanlivosti.

Spôsoby hydrolytickej degradácie
V parou zahrievaných kyslých zmesiach sú aktívne tri degradačné cesty. Prvým je priama hydrolýza polymérneho reťazca. Nad 140 stupňov a v prítomnosti vody a kyseliny je uprednostňovaný útok koncov reťazcov na C-F väzbách. Molekuly vody katalyzujú tvorbu koncových skupín karboxylových kyselín (CF2-COOH), ktoré ďalej katalyzujú degradáciu-autokatalytický proces. FEP má zraniteľnejšie konce reťazcov na jednotku objemu ako PFA, pretože má bočné reťazce -O-CF2-CF2-O-, ktoré sú stabilnejšie vďaka bočným skupinám -CF3. Štúdie zrýchleného starnutia pri 160 stupňoch v 20 % H2SO4 + pare naznačujú, že FEP stráca 15–25 % pevnosti v ťahu po 2000 hodinách a PFA stráca 5–10 %.

Druhým mechanizmom je korózia zrýchlená permeabilitou. Polymérna stena je priepustnejšia pre paru ako pre kvapalnú vodu. Rýchlosť prieniku pary cez FEP (1,0-2,0 g/m2deň pre 2 mm stenu) je 2-3x vyššia ako PFA (0,4-0,8 g/m2deň) pri 150 stupňoch. Zvýšená penetrácia prináša viac pary do kovového jadra a urýchľuje koróziu jadra. Produkty korózie kovového jadra (sírany železa v H 2 SO 4, chloridy železa v HCl) majú väčší objem ako pôvodný kov. To vytvára vnútorný tlak a spôsobuje pľuzgiere a praskanie polyméru zvnútra von. Vyššia permeácia FEP spôsobuje skoršiu tvorbu pľuzgierov.

Tretím mechanizmom je environmentálne stresové praskanie (ESC). Para a kyselina sú činidlá spôsobujúce praskanie napätia, najmä pri teplotách, ktoré sa približujú k bodu topenia polyméru. FEP má nižšiu teplotu topenia (255 stupňov vs Tečenie a relaxácia napätia sú výraznejšie v FEP pri zvýšených teplotách, zatiaľ čo ESC sa vyskytuje pri nižších aplikovaných napätiach. Ohrievač so zvyškovým napätím 3 – 4 MPa z výroby môže prasknúť v FEP do jedného roka pri 170 stupňoch, ale vydrží 5+ roky v PFA.

Údaje porovnávajúce hydrolytickú stabilitu
Parameter FEP PFA Výhoda
Teplota nepretržitého používania (vzduchu) 200 stupňov 180 stupňov PFA +20 stupňov
Teplota topenia (Tm) 305 – 315 stupňov 255 – 265 stupňov PFA +50 stupňov
Miera priepustnosti vodnej pary pri 150 stupňoch, 2 mm steny (g/m2/deň) 0,4–0.8 1.0–2,0 PFA 2–3× nižšia
Zachovanie pevnosti v ťahu po 2000 hodinách v pare + 20 % H₂SO₄ 160 stupňov 85–92 % 70–78 % PFA o 15–20 % lepšie
Predĺženie pri rovnakej expozícii sa zachovalo o 80 – 85 % 55 – 65 % PFA o 25 – 30 % lepšie
Čas na tvorbu pľuzgierov (2 mm stena, para + 30 % H2SO4, 160 stupňov) 3 000 – 5 000 hodín 800 – 1 500 hodín PFA 2 – 3× dlhšie
Stupeň hydrolytickej stability (ASTM D543) pri 150 stupňoch v kyseline/pare 9/10 (výborná) 6/10 (dobrá) PFA lepšia
Steam stress crack resistance 170°C (hours to failure 5 MPa applied stress) >10,000 1,500-3000 PFA 3-5× lepšie
Maximálna prevádzková teplota pre 5-ročnú životnosť v pare + 50% H2SO4 170 stupeň 140 stupňov PFA +30 stupeň
Sprievodca výberom špecifických aplikácií
Kyslá zmes, zahrievaná parou-Zdôvodnenie rozsahu teplôt odporúčaného materiálu
H₂SO4, zriedená (5–20 %) + para<130°C PFA or FEP (both OK)Cost may dictate FEP choice
Zriedená H₂SO4 (5–20 %) + para 130–160 stupňov PFA FEP degraduje po 1–2 rokoch
50-80 % koncentrovanej H2SO{2}} pary<120°C PFA or FEPLimited by acid compatibility
Koncentrovaná H2SO4 (50-80%) + para 120-150 C PFA len FEP zlyháva v mesiacoch
HNO₃ (10–30 %) + para<140°C PFA FEP degrades from oxidation
HCl (10-30%) + para<150°C PFA FEP penetration causes core corrosion
Zmes kyseliny (H₂SO₄ + HNO₃ + H₂O) + para < 160 stupňov PFA len Extrémne podnebie, FEP nevhodné
Digestor (H2SO4 + organické látky) + para 160–180 stupňov PFA s hrúbkou steny (2,5–3,0 mm) PFA na limite; FEP by sa rýchlo zrútil
Autokláv (kyselina + para, dávka) 200 stupňov (prechodná) Žiadne; používajte kremeň alebo kov cez dlhodobé-limity PFA
Poľné údaje pre hydrolýzny reaktor
Chemické zariadenie využívalo dva identické hydrolytické reaktory pracujúce pri 150 stupňoch so vstrekovaním pary na 30 % H2SO4. Reaktor A využíval ohrievač PFA (2,0 mm stena). V reaktore B sa používal ohrievač FEP (2,0 mm stena) počas . 18 mesiacov nepretržitej prevádzky:

Reactor A (PFA): Heater surface showed slight yellowing, no cracking, insulation resistance >200 MΩ, v prevádzke 36 mesiacov.

Reaktor B (FEP): Ohrievač mal niekoľko obvodových trhlín na prírube (praskanie napätím), izolačný odpor klesol na 10 MΩ, vymenený po 22 mesiacoch. Ohrievač FEP mal tiež o 30 % menšie predĺženie pri pretrhnutí ako nový ohrievač.

The plant converted all reactors to PFA and took FEP heaters out of steam acid service >130 stupňov. Počiatočná prémia za PFA (15 – 25 % oproti FEP) sa vrátila v prvom cykle výmeny (22 mesiacov oproti . 36+ mesiacom).

Úvahy o dizajne služby Steam-Acid Service
Pre kyslé zmesi, ohrievané parou, použite PFA, ak je teplota vyššia ako 130 stupňov alebo ak je obsah kyselín vyšší ako 20% a inak použite FEP. Pre prevádzku pri teplotách nad 150 stupňov sú ďalšie požiadavky: (1) Hrubšia stena PFA (2,5-3,0 mm), aby sa znížila priepustnosť a zabezpečila sa erózia. (2) Nainštalujte zberač vlhkosti alebo preplachovanie dusíkom do studeného konca, aby sa zabránilo kondenzácii pary v oblasti terminálu. (3) Obmedzte hustotu wattu na menej alebo 2,5 W/cm², aby sa udržala teplota vnútorného povrchu PFA<200°C. (4) Install a steam deflector for direct steam injection onto the heater to prevent localised superheating. (5) Conduct annual insulation resistance testing; a fall from >1 000 MΩ až<100 MΩ indicates penetration or breaking.

Sledujte ohrievače FEP už v parnej a kyslej prevádzke. Počiatočným indikátorom degradácie je strata lesku povrchu (matná úprava), potom žltnutie, potom praskanie. FEP, ktorý sa stal hnedým, je blízko k zlyhaniu. Výmena PFA sa odporúča pri prvom náznaku degradácie. Žiadne čakanie na únik.

ZÁVER: PFA vykazuje lepšiu hydrolytickú stabilitu pre kyseliny zohrievané parou
PFA is far more suited for long-term use in steam heated acid combinations than FEP because it has a higher temperature capability (200°C vs. 180°C), lower steam penetration (2-3x lower), and superior resistance to stress cracking and hydrolysis. PFA heaters survive 2-5x longer than FEP heaters in service >130 stupňov so silnými kyselinami. Nákladová prémia (15 – 25 %) za PFA je odôvodnená zníženou frekvenciou výmeny, kratšími prestojmi a menším rizikom kontaminácie. V miernych kyselinách pod 130 stupňov FEP poskytuje prijateľný výkon za nižšiu cenu. Technici, ktorí špecifikujú ohrievače pre digestory, hydrolyzéry alebo parné-kyselinové reaktory v akejkoľvek aplikácii, kde je nevyhnutná dlhodobá{8}}spoľahlivosť, by mali špecifikovať PFA. FEP sa dobre hodí pre nižšie teploty alebo menej náročné aplikácie, kde je prijateľná kratšia životnosť. Ak máte pochybnosti, rozhodnite sa pre PFA. Menšie úspory materiálu sú viac než kompenzované poruchou ohrievača FEP v horúcom kyslom kúpeli reaktora{12}}kontamináciou, neplánovaným zastavením a výmenou práce. PFA je normou pre parou zahrievané kyslé zmesi. FEP je výnimkou pre služby s nízkou teplotou alebo{15}}nekritické služby.